Course Catalog 2026-2027

Current Transformer
Online | $300 USD per person

This training is designed for engineers and technicians involved with relay protection. Current transformers are the eyes and ears of relay protection. Incorrect selection of size and class can be catastrophic.

This 2-hour seminar will take you through the basics of current transformers, current transformer saturation due to ac and dc offset currents, selection of appropriate class, and ratio to assure proper relay operation.

You will take away a sound understanding of current transformer selection, saturation due to ac and dc offset currents, classification, and interpreting the saturation curves.  This will enable you to move forward confidently with protection related projects including troubleshooting system events.

Basic Essentials of Protection
Online | $400 USD per person

This 4-hour virtual training is designed for technicians who are seeking to enhance your knowledge in the area of relay protection. Become proficient in testing protection schemes and troubleshooting and basic electrical theory that will help you perform effective testing of relays and also conduct diagnostics. This diagnosis is needed during testing relay protection systems and will help you analyze misoperations of relays during system faults.

Course Outline

  • Basic electrical theory
  • Basic relay protection theory
  • IEEE device numbers
  • Become familiar with various protection-related drawings
  • Types of protection used in a power system
  • Brief description of each type of protection
  • Transformer connections
  • Testing procedures for testing different types of protection

Tutorial on Protection Suite
Online | $400 USD per person

This 4-hour webinar is designed for technicians involved with testing of protective relays. This webinar will provide a tour of Protection Suite enabling the attendees to get familiar with various features of this software.

Course Outline

  • File structure
  • Preparing test plans using macros
  • Use of formulas
  • Use of Control panel to conduct manual testing
  • State Simulation
  • Using State Simulation to create test plans
  • Report generation
  • Importing settings from microprocessor relays
  • Brief description of the F6150 test set

RTS Essentials
Tulsa, OK & Online | $1600 USD per person

This webinar provides a chance to get up-to-speed in a hurry. Technicians and engineers who are new to relay testing that need to learn the basics behind what RTS does and become proficient with using RTS will want to attend this course.

Course Outline

  • How to use RTS for standardization with ROUTINE SELECTION operations
  • Operating test equipment with RTS
  • How to modify Library and System routines
  • How to modify and create new tests with FasTest module
  • Testing relays using RTS
  • Understanding VIEW RESULTS selection operations
  • How to merge relay information with BACKUP selection operations
  • Helpful problem-solving techniques

RTS Developer
Tulsa, OK & Online | $1600 USD per person

The RTS interface is built entirely for test manipulation. During this course, attendees will be exposed to all of the numerous tools and techniques available for creating or customizing any test routine. Moving beyond test plan modification, attendees will learn about RTS commands and gain insights that will be useful as they develop new test routines of their own.

RTS Essentials is a pre-requisite to this course. We will verify Essentials training has previously occurred for all attendees.

Course Outline

  • Creating new test routines using the FasTest module
  • Features within the FasTest module to assist in routine customization
  • Methods to automate the population of settings into SETTINGS tab
  • Introduction of RTS COMMANDS
  • Displaying messages to Users
  • Utilization of RTS COMMANDS to create intelligent routines
  • Working with String Variables
  • Communication to the SEL relay

RTS Advanced Developer
By Request | $1600 USD per person

The FasTest system has revolutionized the speed and ease in which a basic to complex test procedure can be created. This system has eliminated 90%+ of the problems customers had with test procedures using traditional code. Course participants will learn how to create new test procedures/routines from scratch.

Even though the method has been highly accepted, there are those who desire to extend their control of the test routine while still utilizing the power and ease of the FasTest system. This training is to inform Users of the power available “Beyond FasTest”.

“Beyond FasTest” sessions will be lecture and examples given by the instructor. Class participants will be given an overview of the material with areas for personal notes.

Course Outline

  • Overview of creating fastest routines
  • Methods of entering settings into setting tab
  • Introduction to RTS commands
  • Displaying messages to the user
  • Incorporating complex calculations into a fastest test procedure
  • Power of string variables
  • Explanation of current utilization of SEL communication commands
  • Explanation of all SEL communication commands currently available
  • Methods available for retrieving settings from a GE-UR series or siemens relay
  • Utilizing macros within a fastest test procedure
  • Fastest “test_type” flag
  • Customizing existing test result printouts
  • Creating fully customized test result printouts

Motor Protection Training
Online | $300 USD per person

This 2-hour virtual training is designed for engineers and technicians who are seeking knowledge in the area of motor protection in an easy to understand format. All protective elements applied at motors will be presented including setting guidelines.

Course Outline

  • Overload
  • Locked rotor
  • Load jam
  • Ground fault
  • Differential
  • Phase reversal
  • Current Unbalance
  • Load loss
  • Undervoltage
  • Overvoltage
  • Surge protection

Generator Protection Training
Online | $520 USD per person

This 4-hour virtual training is designed for engineers and technicians involved with generator relay application and settings criteria. Several elements applied to protect the generator will be discussed in detail along with guidance for setting these elements.

Course Outline

  • Differential Protection (detailed discussion on differential included)
  • Stator ground fault (including 100% winding protection)
  • Negative sequence
  • Loss of field
  • Out-of-step
  • Reverse power
  • Backup protection
  • Rotor ground fault
  • Over/under frequency
  • Accidental Energization

Generator Protection Theory & Hands-On Testing of Protective Elements
Morrisville, NC | $2000 USD per person

This 3 day in person class deals with the theory of generator protection and hands on testing of different protective elements such as differential, loss of field, reverse power, out-of-step, backup protection, ground fault, etc.

Designed for:

  • Engineers, managers, technicians who deal with power plants and industrial plants with in-house generation
  • Insurance personnel
  • Designers of power plant protection
  • Fresh graduates

Course Outline

  • Backup Protection both distance and voltage restraint
  • Loss of field
  • Reverse Power
  • Over/under Frequency
  • Differential Protection
  • Out-of-Step
  • 100% ground fault protection
  • Negative Sequence
  • Inadvertent Energization
  • Theory and Hands on Testing of each element will be covered

System & Generator Neutral Grounding
Online | $400 USD per person

This 2-hour virtual training is designed for engineers and technicians involved with protective relaying and system design. There are many ways in which the neutrals of transformers and generators can be grounded. 

This training presents the advantages and disadvantages of each type, including 100 percent ground fault protection for generators. Sizing of resistors, and grounding transformers including zig-zag transformers will be dealt with in detail.

Harmonic Simplified & Filter Design
Online | $650 USD per person

This one-day online theory class deals with the harmonics in a power system. Presence of harmonics in a power system has been an issue for a very long time. However, the situation has been accelerated significantly due to introduction of renewables, battery energy storage systems and data centers. Several challenges have been presented to the power grid such as loss of inertia, erratic loading of AI data centers, etc. along with the significant flow of harmonics into the power grid and especially transformer performance. This session will cover the harmonic aspect including remedial measures.

Designed for:

  • Engineers, managers, technicians who deal with renewables including battery energy storage systems, and data centers.
  • Insurance personnel
  • New graduates

Fundamentals of Renewables
Online | $450 USD per person

This 4-hour virtual training is designed to present an overview of wind and solar power along with issues associated with integrating renewables into power grid. The material presented in this course will provide attendees a very good understanding of renewables.

Course Outline

  • Types of wind power generation
  • Short circuit output of each type of wind power generators
  • Issues and solutions related to relay protection
  • Harmonic generation by each type and solutions
  • Impact of harmonics on transformers applied at renewable plants
  • Impact of erratic loading on transformers
  • Basic information of solar plants
  • Harmonic generation by solar plants and solutions
  • Relay protection applied at solar plants
  • Setting orientation of solar panels to capture maximum energy

 

Fault Calculations & Symmetrical Components
Online | $650 USD per person

This virtual training is designed for engineers and technicians involved with protective relaying. Knowledge of fault current including symmetrical components is a must for protection engineers and engineers involved with electrical equipment. Any analysis of system events involving protective relaying requires a sound knowledge of fault analysis.

Course Outline

  • Calculation of three phase faults using Ohmic method
  • Per unit method for simplifying fault current calculations
  • Worked-out example using per unit method— 3ph, ph-ph, and ph-ground
  • Typical values of per unit impedances for generators, motors, transformers, etc.
  • Basic concept of symmetrical components and using them to calculate fault currents
  • Fault current relationship involving different transformer connections
  • Worked-out example using a commercial software
  • Symmetrical and unsymmetrical components of fault current
  • What is DC offset?
  • Response of relays to DC offset
  • Relay response depends on time elapsed since fault inception
  • Fault current duties experienced by interrupting devices such as fuses, breakers, etc.
  • Evaluation of interrupting devices based on first cycle duty and symmetrical duty

Transformer Differential Application & Testing of Differential Function Training
Online | $650 USD per person

This virtual, one-day training is designed for engineers and technicians involved with transformer relay applications, settings criteria, and testing. This combination of theory and step-by-step testing procedure for each protective element is unique and will bridge relay application, settings, and testing. You will learn the theory in a much easier way and the technicians will be able to test protective functions in a meaningful manner.

This training will deal with the differential protection applied at transformers which will include detailed theory and testing methods for slope characteristics, harmonic blocking/restraint, high set instantaneous using Doble protection software Protection Suite.

Line Differential—Theory & Testing Procedure Training
Online | $300 USD per person

This 2-hour virtual training is designed for engineers and technicians who are seeking knowledge in the area of line current differential. The relays used will be the ones that implement line current differential using the alpha plane. The testing procedure will be shown and will be followed by a detailed explanation of the alpha plane. The material is presented in a very easy to understand format.

Line Protection Using Step Distance & High-Speed Communication Training
Online | $520 USD per person

This virtual training is designed for engineers working in the area of relay protection. Engineers with varying level of experience will gain valuable information related to application and settings.

This theory course will provide a detailed information related to distance protection along with protective schemes such as step distance and communication assisted protection (DCB, POTT, DTT, etc.). The material is presented in a very easy to follow format.

Course Outline

  • Basic working of distance relays
  • Detailed theory of distance protection
  • Mho and Quad characteristics
  • What is zero sequence compensation
  • Detailed analysis of step distance protection
  • Criterion for settings time delays for various zones
  • Shortcomings of step distance
  • Basics of communication assisted protection
  • Communication channels
  • Detailed description of POTT, DCB, and DTT.

High Speed Protection & End-End Testing
Online | $400 USD per person

This 4-hour online course is designed for engineers and technicians who are seeking knowledge in the area of high speed protection and end-to-end testing.

A detailed procedure for running an end-to-end test using state simulation and COMTRADE files will be provided. Test plans will be created and these tests will be used to verify a POTT and a DCB scheme.

End-End testing to verify the performance of line current differential will also be presented.

Course Outline

  • Theory
    • Overview of distance protection including step distance
    • Basis for high speed protection
    • Different types of channels in use
    • High speed protection – DCB, POTT
    • Overview of line current differential including alpha plane
  • End-to-End Testing

Relay Application & Hands-On Testing of Overcurrent Elements of a Microprocessor Relay Training
Morrisville, NC & Online | $400 USD per person

This 4-hour training is designed for technicians involved with the testing of protective relays. This training will discuss the theory of the overcurrent element of a microprocessor relay followed by a step-by-step procedure for testing all functions of this element. The test plan creation will be done using Doble testing software Protection Suite. In the process of creating the tests, an excellent overview of the testing software will also be included.

Course Outline

  • A brief overview of relevant sections of Doble testing software Protection Suite
  • A brief overview of Doble test set F6150
  • Description and theory of the overcurrent element, and logic setup within the relay
  • Create tests for minimum pickup of time overcurrent, timing test, instantaneous pickup

Relay Application & Hands-On Testing of Distance Elements of a Microprocessor Relay Training
Morrisville, NC & Online | $400 USD per person

This 4-hour training is designed for technicians involved with the testing of protective relays. We will discuss the theory of distance relays of a microprocessor relay followed by a step-by-step procedure for testing all functions of this element. Both phase and ground distance elements will be covered. The test plan creation will be done using Doble testing software Protection Suite. In the process of creating the tests, an excellent overview of the testing software will also be included.

Course Outline

  • A brief overview of relevant sections of Doble testing software Protection Suite
  • A brief overview of Doble test set F6150
  • Description and theory of the phase and ground distance elements, and logic setup within the relay
  • Create tests for minimum pickup of distance elements, max torque test, and characteristic plotting

Relay Application & Hands-On Testing of Overcurrent Elements of an Electromechanical Relay
Morrisville, NC & Online | $400 USD per person

This 4-hour training is designed for technicians involved with the testing of protective relays. This training will discuss the theory of electromechanical relays followed by a step-by-step procedure for testing all functions of an electromechanical overcurrent relays. The test plan creation will be done using Doble testing software Protection Suite. In the process of creating the tests, an excellent overview of the testing software will also be included.

Course Outline

  • A brief overview of relevant sections of Doble testing software Protection Suite
  • A brief overview of Doble test set F6150
  • Description of the relay, its components, and theory
  • Create tests for minimum pickup of time overcurrent, timing test, instantaneous pickup, and target test

DP005 | Relay Application & Hands-On Testing (Basic Level)
Morrisville, NC | $1800 USD per person

This course covers the testing of simple overcurrent relays such as time overcurrent, under/overvoltage, and over/under frequency electromechanical and microprocessor relays.

Designed for:

  1. Junior level technicians who are involved with testing of electro-mechanical/microprocessor relays
  2. Technicians who wish to enhance their knowledge of testing simple relays/elements such as overcurrent, over/under voltage and over/under frequency relays
  3. Technicians who wish to learn how automated testing is performed in addition to the manual testing that they are practicing presently

Course Outline

  • Day 1
    • Introduction to protection
    • Reading a three line diagram and schematic diagram
    • Construction and operating principles of electromechanical relays (induction disk, plunger type, magnetic attraction type)
    • Construction and operating principles of microprocessor relays
    • How to read characteristic curves
    • How to use characteristic curves to come up with operating times
    • How is directionally determined
    • Operating and polarizing quantities
    • Hands on testing of overcurrent relays
  • Day 2
    • Hands on testing of over/under voltage relays and over/under frequency relays
  • Day 3
    • Hands on testing of directional over current relays

DP006 | Relay Application & Hands-On Testing (Intermediate Level)
Morrisville, NC | $1800 USD per person

This course deals with the testing of distance, differential, negative sequence overcurrent, reclosing, sync check, and breaker failure. The course will start with the theory related to distance and differential functions followed by hands on testing.

A brief description of operating principles of these relays will also be presented followed by hands on testing of these relays using Doble relay test sets. Both manual and automated testing using a test plan will be used for training. A combined application course coupled with hands-on training.

Designed for:

  1. Senior and Junior level technicians who are involved with testing of electro-mechanical/microprocessor relays
  2. Technicians who wish to enhance their knowledge of moderately complex relays
  3. Technicians who wish to learn how automated testing is performed to test moderately complex

Course Outline

  • Day 1
    • R-X Diagram
      • Basic elements of an R-X diagram
      • How do we use it to represent load, line impendence, etc.
      • How do we use this diagram to observe distance relay behavior using this diagram?
    • Distance Protection
      • Basic principles
      • Characteristics & operating principles of Mho and Quad
      • Polarization for phase and ground distance
      • Determination of directionality
      • Step distance protection using distance relays
      • Infeed effect
      • Impact of arc resistance
      • K-factor used in ground distance
      • Expanding Mho characteristics
      • Zone 1 acceleration
    • Differential Protection
      • Vector compression
      • Amplitude compensation
      • Handling various transformer connections
      • Harmonic restraint
      • Zero sequence elimination for external faults
  • Day 2
    • Testing of differential relays
  • Day 3
    • Testing of Sync. Check function
    • Testing of a Reclosing function of a microprocessor relay
    • Testing of a Breaker Failure Function
    • Testing of a Negative Sequence overcurrent function

DP007 | Relay Application & Hands-On Testing (Advanced Level)
Morrisville, NC | $2000 USD per person

Examine advanced testing involving communication assisted protection, analysis of even reports, COMTRADE and ss1 files, line current differential relays, bus differential protection testing. Out-of-step testing concept will be presented. Each testing section will be preceded by the theory on related relaying.

Designed for:

  1. Senior level technicians who are involved with testing of electro-mechanical/microprocessor relays
  2. Technicians who wish to enhance their knowledge of reading event reports, complex relaying, advanced testing techniques, end-to-end testing, out-of-step relaying, bus differential and line current differential

Course Outline

  • Day 1
    • Communication Assisted Protection
      • Basic concept of communication assisted protection
      • Description of different communication channels (Power line carrier, fiber, etc.)
      • Schemes
        • Blocking
        • Unblocking
        • POTT
        • PUTT
        • DTT
      • Sequential trip
      • Remote breaker Open
      • Weak Infeed
      • Analyzing Event and Sequence of Event Reports
      • COMTRADE Files
      • SS1 files
    • Testing: 
      • Replaying COMTRADE files and analyzing reports generated by target relays.
      • Analyze sample event report and sequence of events
      • Set up end-to-end test
      • Run the tests and analyze the results using Doble software and COMTRADE files from the relays
  • Day 2
    • Testing
      • Run the tests using Doble State Simulation and SS1 files and analyze the results using Doble software and COMTRADE files from the relays
      • Line Current Differential
        • Basics of line current differential
          • Different methods used to perform line current differential relaying
    • Testing
      • Test various elements of line current differential relaying
    • Bus differential relaying
      • Basics of Bus differential relaying
      • High impedance and low impedance bus differential
  • Day 3
    • Testing
      • Test high impedance bus differential relaying
      • Testing low impedance bus differential relaying (SEL 487B)
    • Out-of-Step Protection
      • What are power swings?
      • Stable and unstable swings
      • Various methods of detecting unstable swings
      • Blocking and tripping functions in relays related to out-of-step protection

Looking for something different? Email events@doble.com to coordinate specialized, on-site trainings with our experts today.