Distribution Protection Track
Earn up to 3.0 CEUs or 30 PDHs
The Distribution Protection Track caters to those requiring a thorough knowledge of protection, control, and power quality monitoring of electric power distribution systems, including strategies to address challenges arising from the significant presence of Distributed Energy Resources (DER).

Sunday, July 26, 2026
5:00 PM - 7:00 PM
Seminar Check-in
- Please check-in for the seminar and pick-up your badge sometime between 5:00-7:00 PM on Sunday, July 26th.
- If you can't make it on Sunday, please stop by the Help Desk sometime between 7:00-8:00 AM on Monday, July 27th.
Monday, July 27, 2026
7:00 AM - 8:00 AM
Breakfast & Attendee Check-in
Please check-in for the seminar and pick-up your badge at the Beckwith Electric Help Desk.
8:00 AM - 8:30 AM
Welcome & Introductions
8:30 AM - 9:45 AM
Distribution Feeder Protection – IEEE C37.230
- Distribution System Reliability
- Standards and Practices
- IEEE C37.230 (Guide for Protective Relay Applications to Distribution Lines)
- Protection Philosophies
- Causes of Faults
- Fault Types
- Distribution System Construction and Configurations
- Impedances Used in Fault Current Analysis
9:45 AM - 10:00 AM
Break
10:00 AM - Noon
Distribution Feeder Protection – IEEE C37.230 (Continued)
Noon - 1:00 PM
Lunch
1:00 PM - 3:00 PM
Fault Fundamentals and Basic Event Analysis
3:00 PM - 3:15 PM
Break
3:15 PM - 5:00 PM
Distribution Feeder Protection & Control
Distribution protection is a complex scenario with many elements: relayed feeder breakers, recloser controlled feeder breakers, line reclosers, sectionalizing switches, sectionalizers and fuses. The application and location of the protective and sectionalizing infrastructure predicates the application and coordination of protection. Compounding the complexity is the application of DMS/DA and presence of DER/DG. The session covers the distribution topology and protective infrastructure, and application of settable of relays and recloser controls.
- Fault Calculations and Settings
- Protection Devices and Characteristics
- Protective Device Selection and Application
- Protective Functions of Relays and Controls
- Ground Fault Detection Method
- Automatic Reclosing
- Time Overcurrent Device Coordination
- Special Protective Applications
- Fault Event Analysis
Tuesday, July 28, 2026
7:00 AM - 8:00 AM
Breakfast
8:00 AM - 9:45 AM
Feeder Protection Calculations & Settings
- Feeder Protection Calculations Example
- Short Circuit Current
- Per Unit Quantities
- Symmetrical Components
- Fault Types
- Fault Current Calculations Example
9:45 AM - 10:00 AM
Break
10:00 AM - Noon
Distribution Automation: FLISR
This session will focus on various Fault, Location, Isolation, and Service Restoration (FLISR) schemes. FLISR is utilized to limit the number of customers affected by a permanent fault by isolating the fault and utilize other sources to reconfigure the system to restore as many customers as possible. The proliferation of Distributed Energy Resources (DER) also needs to be taken into account with distribution automation. These schemes vary in complexity from simple throw over, to more complex loops utilizing peer-to-peer IED communication, and the most advanced that incorporates system models. Scripted or logic-based FLISR schemes will be compared to ones that incorporate system models, from more simplistic models to full Geographic Information Systems (GIS) integration.
Noon - 1:00 PM
Lunch
1:00 PM - 2:45 PM
Distributed Energy Resources Operation, Control & Protection – IEEE 1547
Distributed Electric Resource (DER) is increasing its penetration into the distribution system. This technical session provides a background into DER operation and associated control and protection considerations for conventional and inverter-based power sources. We will review types of DER/DG and the modes in which they can operate in parallel with the distribution system. Key aspects of IEEE 1547 and a sample DER interconnection screening process are highlighted. Details of on-site standby power system conversion to operate in parallel with the distribution system are shown. Protection methodology at the point-of-common coupling (PCC) and point-of-interconnection (PI) is explored for all types of DER. A treatment of distribution system protection and control considerations and applications with DER is discussed.
- Define Distributed Electrical Resource (DER)
- Explore Types of DERs
- Why DER?
- Utility and Facility Drivers for DER
- Mission Critical Power and Conversion to DER
- Rates and DER Operational Sequences
- Industry Concerns
- IEEE 1547 (Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces)
- Sample Utility DER Interconnection Guide
- Interconnection Protection: “The Five Food Groups”
- Anti-islanding
- Powerflow
- Fault detection
- Abnormal operating conditions
- Reconnection
- Interconnection Transformer Impacts
- Generator Types and Impacts
- Synchronous
- Induction
- Asynchronous (Inverter Based)
- Example Protection Applications
- Distribution Protection Coordination Issues
- Directionalization
- Reclosing coordination
- Smart Grid / Microgrid and DER
- Impact of IEEE 1547-2018
- Fault ride-through
- Reactive support and voltage control
- System Control with DER
- LTC, Regulator and Capacitor Control Issues
2:45 PM - 3:00 PM
Break
3:00 PM - 4:00 PM
Cybersecurity
4:00 PM - 5:00 PM
Introduction to Applications for IEC61850 in Distribution Systems
Wednesday, July 29, 2026
7:00 AM - 8:00 AM
Breakfast
8:00 AM - 9:45 AM
Transformer Protection – IEEE C37.91
Transformers are subject to internal faults, the effects of external faults and abnormal operating conditions impressed by the power system events the transformer has no control over but must cope with. False (nuisance) trips are costly as the transformer and load are disconnected. Inability to trip due to lack of sensitivity, lack of certain protections or deficiencies in protection application may cause severe damage to transformers, negatively impacting power flows, impacting power quality and compromising stability. Achieving the ideal balance of secure and dependable protection involves use of an array of elements that protect the transformer from prolonged internal faults, excessive through faults and when challenged by power system faults and anomalies.
- IEEE C37.91 (Guide for Protecting Power Transformers)
- IEEE Devices used in Transformer Protection
- Transformer Protection Review & Functions
- Explore Protection Functions
- 87T Phase Differential Characteristic
- Compensation in Digital Relays
- Relay Configuration: Winding Arrangement and CT Connection
- Overcurrent based (50, 51, 50N, 51N, 46)
- Through fault protection (TFM)
- Overexcitation (24)
- Generating plant causes
- T&D system causes
- Protection Against Overexcitation – V/Hz versus 5th Harmonic
- Phase Differential (87T)
- Unique Issues Applying to Transformer Differential Protection
- CT performance issues (saturation, remnant flux, tolerance, rating)
- Percentage differential characteristics with variable percentage slopes
- Internal ground fault sensitivity
- Restraints for inrush and overexcitation
- Overexcitation 87T Blocking Restraint – Failure to detect nascent fault
- Overexcitation Adaptive 87T Pickup Restraint – Detects nascent faults
- Adaptive restraint for security
- Point-on-Wave Switching Inrush
- Cross Phase Averaging
- Switch-onto-Fault
- High Set Phase Differential (87H)
- Ground Differential (87GD), Restricted Earth Fault (REF)
- Interface and Analysis Software: Desirable Attributes
- NERC “State of Reliability”
9:45 AM - 10:00 AM
Break
10:00 AM - Noon
Transformer Protection – IEEE C37.91 (Continued)
Noon - 1:00 PM
Lunch
1:00 PM - 2:45 PM
Advanced Transformer Protection – IEEE C37.91
2:45 PM - 3:00 PM
Break
3:00 PM - 5:30 PM
Transformer Protection Calculations & Settings
Building on the base knowledge covered in Transformer Protection Fundamentals, calculations for protective elements are developed. Depending on the element, these calculations use nameplate data, system data or a combination of the two. Margin considerations are explored and impacts on element reliability are discussed, as well as element interdependencies with protection and control in the transformer zone, whether in generation, transmission or distribution.
Thursday, July 30, 2026
7:00 AM - 8:00 AM
Breakfast
8:00 AM - 9:45 AM
Distribution Automation
Learn how to test recloser controls. This includes procedures, best practices, and practical field experience using testing tools from the major test set vendors.
9:45 AM - 10:00 AM
Break
10:00 AM - Noon
Distribution Automation (Continued)
Noon - 1:00 PM
Lunch
1:00 PM - 2:30 PM
Power Quality (PQ) Metering and Phasor Measurement (PMU)